Skip to main content

The knife did not reach the extended position

  • Test for free movement of the knife by hand
  • Check system air pressure
  • Press F3 to open IO screen to check DI 6 for illumination. If knife is extended and DI 6 is not illuminated, then check the cylinder proximity sensor. There should be a yellow light indicating cylinder position.
  • Use the manual controls to test movement
Knife extended indicator light