The block did not reach the extended position
- Test for free movement of dough block by hand
- Check system air pressure
- Press F3 to open IO screen to check DI 8 for illumination. If block is extended and DI8 is not illuminated, then check the cylinder proximity sensor. There should be a yellow light indicating cylinder position.
- Use the manual controls to test movement