- Remove the front panel and check the pressure of the compressor tank.
- Ensure that the system and air compressor are plugged in and switched on. Pressing the start cycle button will reset the compressor automatic shutoff timer.
- If everything is on and the system is in cycle but the compressor will not turn back on to build more pressure, check that the compressor is not in an airlock condition
- If the compressor is running and outputting 90PSI, check the pressure regulators to ensure they are set correctly, and the filters are not clogged.