Skip to main content

The block did not reach the retracted position

  • Test for free movement of dough block by hand
  • Check system air pressure
  • Press F4 to open IO screen to check DI 9 for illumination. If block is retracted and DI9 not illuminated, then check the cylinder proximity sensor. There should be a yellow light indicating cylinder position.
  • Use the manual controls to test movement
Block retracted indicator light